BAE is a peat formulation that stimulates microbial growth and activity in both University Studies and
real world applications
Aerobically BAE increases coagulation, improves removal of BOD, TSS, and metals
Anaerobically increases methane production and VSD
Landis Sewerage Authority is an 8.2 MGD designed plant with average BOD influent of 350 mg/l. BAE improved coagulation and aeration performance creating aeration challenges.
BAE improved anaerobic performance and methane production accelerating their CHP operations and was awarded the EPA "1st Place Energy Star Award"
Joint Meeting of Essex and Union Counties is an
85 MGD plant located in Elizabeth New Jersey. The facility consists of four 1.77-million-gallon digesters with cannon mixers
BAE significantly increased methane production by 40%, VSD by 16%, dewatering from 82% to 86%, saving the facility over $880,000 annually
Gloucester County Utility Authority is a 24 MGD located in Deptford N.J.. BAE improved aeration and reduced MLSS by as much as 50%. Secondary clarifiers experienced improved settling. WAS increased by as much as 100% and gravity belt thick operations improved significantly saving the GCUA
over $465,000 annually.
Cinnaminson Sewerage Authority is a 2.2 MGD designed plant located in Cinnaminson New Jersey discharging into the Delaware River
Adding BAE to the system, was able to reduce their
suspended solids by 125 lbs. per day, reduced their sludge disposal costs and chemical costs, saving over
$100,000 annually in expenses
ewistown WWTP a 2 MGD plant is located in rural Pennsylvania. Heavy rains wash out the plant regularly forcing the addition of bacteria and polymer to keep the plant within permit
BAE brought back the biology eliminating the addition bacteria & polymer, and wash out disruptions, saving the plant over $21,000 annually
The Hayward facility is an 18.5 MGD plant in Hayward California. Prior to adding BAE, the plant hired an accredited university to test BAE and finding it to increase biogas 48%. Adding BAE to their digester increased generator run time 100%, improved
VSD performance, and in 6-months saved the
plant $28,000 in energy.
AUA is located in Bridgeton N.J.. It's an activate sludge system with an anaerobic digesters and a flow of 3.5 MGD with a BOD of 600 mg/l from food manufacturing placing pressure on their systems
BAE improve aeration, secondary settling, raised their anaerobic digester VSD, and improved the sludge dewatering process